Fujitsu MHY2120BH Manual Do Utilizador
1.3 Power Requirements
C141-E262
1-7
1.3 Power Requirements
(1) Input Voltage
•
+ 5 V
± 5 %
•
It is unnecessary for this drive to supply +3.3 V and +12 V power supplies.
(2) Ripple
+5
V
Maximum
100 mV (peak to peak)
Frequency
DC to 1 MHz
(3) Slope of an input voltage at rise
The following figure shows the restriction of the slope which is +5 V input
voltage at rise. The permissible range of +5 V slope is from 1V/20
voltage at rise. The permissible range of +5 V slope is from 1V/20
µsec to
1V/20 msec, under the voltage range is between 2.0V and 4.5V.
Figure 1.1 Permissible range of +5V rise slope