10.7.2.2 Diagnostic Mode  
 
The drive enters diagnostic mode immediately after the power -on or after an Execute Diagnostics 
command. Error bit in Status Register shall not be set in these cases. The following table shows bit values 
for the diagnostic mode.   
Table 10.7-1    Diagnostic mode error register 
01 No 
errors 
 
02 
Controller register error     
03 
Buffer RAM error 
04 
ECC device error 
05 
CPU ROM/RAM error 
06-7F Reserved 
8x 
Drive1 error (see below) 
 
When two drives are daisy-chained on the interface, the Drive0 has valid error information for diagnostic 
mode.    When the Drive1 detects an error, 80H and OR value (01∼04) diagnosed by the Drive0 are set to 
the code above mentioned.   
10.7.3  Features Register (Write Precompensation Register) 
 
  - CS0 
 DA2-DA0 : 1
 Write only 
 
Write precompensation is automatically optimized by the drive internally.    This register is used with Set 
Features command. 
10.7.3.1 Smart command 
This command is used with the Smart commands to select subcommands. 
10.7.4  Sector Count Register 
 
    - CS0 
  DA2-DA0 : 2
  Read / Write 
 
10.7.4.1  Disk Access command 
The sector count register determines the number of sectors to be read or written for Read, Write, and Verify 
commands.    A 0 in the sector count register specifies a 256 sector transfer.    After normal completion of a 
command, the content shall be 0. 
During a multi-sector operation, the sector count is decremented and the sector number is incremented.    If 
an error should occur during multi-sector operation, this command shows the number of remaining sectors 
in order to avoid duplicated transfer. 
10.7.4.2  Initialize Device Parameters command 
This register determines number of sectors per track. 
10.7.4.3  Power Control command 
This register returns a value in accordance with the operation mode (idle mode or stand-by mode). 
10.7.4.4  Set Features Command 
If features register for this command is 03h, this register sets the data transfer mode.