10.8.16  Initialize Device Parameters    (91h) 
 
COMMAND CODE 
1 0 0 1 0 0 0 1
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
drive number 
no change 
CY  
no 
change 
HD 
total number of heads-1 
no change 
SN 
number of sector per track 
no change 
SC  
no 
change 
FT  
no 
change 
 
 
This command specifies the number of sectors per track and the number of heads per cylinder to set head 
switching point and cylinder increment point. Specified values affect Number of the current logical heads, 
Number of logical sectors per track, which can be read by Identify Device Command. 
On issuing this command, the content of CY register shall not be checked. This command will be terminated 
with ABORT error when it is issued on a invalid HD or SC register setting ( SC register=0 or the combination 
of HD and SC register exceeds the drive parameter.         
Any drive access command should accompany correct HD, SN register with heads and sectors within the 
number specified for this command.    Otherwise, it results in “ID not found” error.    If the number of heads 
and drives is within the specified number, command gives parameter to convert an address to access into 
Logical Block Address (LBA). 
  ID Not Found
error also occur when this LBA exceeds the total number of 
user addressable sectors.    The command does not affect LBA address mode.