10.8.31  SET MAX (F9h) 
Individual SET MAX commands are identified by the value placed in the Features register. Table 10.8-6 shows 
these Features register values. But regardless of Feature register value, the case this command is immediately 
proceded by a Read Native Max ADRESS comamnd, it is interpreted as a Set Max ADDRESS command. 
 
Table 10.8-6    SET MAX Features register values 
Value Command 
00h Obsolete 
01h 
SET MAX SET PASSWORD 
02h 
SET MAX LOCK 
03h 
SET MAX UNLOCK 
04h 
SET MAX FREEZE LOCK 
05h-FFh Reserved 
 
 
10.8.31.1  Set Max Address   
     
COMMAND CODE 
1 1 1 1 1 0 0 1
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
DRIVE No. 
no change 
CY 
Max. cylinder number 
no change 
HD 
Max. head number 
no change 
SN 
Max. sector number 
no change 
SC 00
H
 / 01
 H 
  (BITO: reserved bit) 
no change 
FT  
no 
change 
LBA 
Max. LBA 
no change 
 
  This command specifies the the maximum address in a range of actual drive capacity. The values set in CY, 
HD, SN registers indicate the maximum address that can be accessed. In CHS mode, the value of Read Native 
Max Address command should be set in HD, SN register. Otherwise, the value shall be ignored and the value of 
Read Max Address command will be used. If an LBA bit (DRV / HD register bit 6) is set, the value in LBA mode 
shall be set. If the address exceeding the set value is accessed , “ ABORT ERROR “ error will be reported. This 
set value affects the values of WORD 1, 54, 57, 58, 60, 61, 100-103 of IDENTIFY DEVICE command.   
  This command shall be immediately preceded by Read Native Max Address command. Otherwise, it will be 
terminated with “ ABORT ERROR ” . 
  If this command is issued twice with a volatile bit set to 1 after power-up or hardware reset,    “ID Not Found 
error” will be reported. 
  If a host protected area has been established by a SET MAX ADDRESS EXT command, this command will be 
terminated with “ ABORT ERROR ” . 
Volatile bit ( SC register bit 0 ) :   
  If this command is issued with a volatile bit set to 1, the set value of this command is valid after power-up or 
hardware reset. 
  If this command is issued with a volatile bit cleared to 0, the set value of this command shall be cleared after 
hard reset or power-on and the maximam value shall be the last value with a volatile bit set to 1.