Rear Termination Panel 
The R FR 5010/ R FR 5011 has an integral termination 
panel on the rear of the rack for the connection of 
power and various other connections for expansion 
and interfacing. Figure 5  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
          Figure 5 Rear Panel Connections 
Rack Connections 
Power Connection 
There are two power connections provided for the 
rack. One is for primary power and the other for the 
optional redundant power supply. Input power 
range is 100 to 240VAC 50 to 60Hz. Connection is 
made using an IEC power cable. For systems 
without redundant power connection is made to 
AC1 in only. The power fuse is in the connector 
assembly (Figure 5) and removal of this small 
module will enable fuse exchange. Please ensure 
you use the correct fuse rating. (2A).