Yamaha ERCX Manual Do Utilizador

Página de 52
34
CHAPTER2  Ethernet Unit
Checkpoints
• Check the TELNET parameter to find 
if it was set to stop operation during 
logout.
• Check the TELNET parameter to find 
if communication status is longer than 
the time set for timeout.
• Check if a cable is detached or power 
supply for the HUB or other equipment 
is off.
• Check if operating problems are 
occurring in devices such as the HUB 
due to noise, etc.
• Too short of a period was set for the 
no-response timeout period.
• Try substituting with another Ethernet 
unit.
Action
• Always use a LOGOUT or BYE 
command to terminate a TELNET 
communication.
• Reset the parameter so operation 
continues during logout.
• Set so communication time does not 
exceed the timeout limit. Otherwise 
increase the communication timeout 
period or disable the timeout function.
• Check the network and repair/restore 
any problem locations.
• Replace a device having operating 
errors with another device.
• Set the no-response timeout period to 
match the network structure and traffic 
conditions. Or disable the timeout 
function.
• If operation returns to normal, then the 
Ethernet unit is defective so replace it.
No.
4
Probable causes
TELNET 
communication 
cuts off by itself 
without a 
LOGOUT or 
BYE command 
being issued.
TELNET 
parameter was 
set to stop 
operation during 
logout.
Communication 
status continues 
for a fixed period 
and then cuts off 
automatically at 
timeout.
No-response 
status continues 
for a fixed period 
versus the keep-
alive packet and 
then cuts off 
automatically at 
timeout.
Ethernet unit is 
defective.
1)
2)
3)
4)
5)
Symptom
Program 
stops by itself 
during 
automatic 
operation.