AC Electrical Characteristics
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
–
Serial Input Data Rate
–
143
–
1485
Mbps
V
SDI
Input Voltage Swing
Single-ended, at the transmitter,
HD data rate
HD data rate
500
1200
mV
V
SDI
Input Voltage Swing
Single-ended, at the transmitter,
SD data rate
SD data rate
500
1200
mV
ΔV
SDO
Output Voltage Swing
Differential
p-p
, 50
Ω load
450
700
950
mV
–
Output Jitter for Various Cable
Lengths and Data Rates
Lengths and Data Rates
270 Mbps
Belden 1694A: 0-175m
Canare L-5CFB: 0-175m
800 mV transmit amplitude
Equalizer pathological pattern
Belden 1694A: 0-175m
Canare L-5CFB: 0-175m
800 mV transmit amplitude
Equalizer pathological pattern
–
0.2
–
UI
1.485 Gbps
Belden 1694A: 0-70m
Canare L-5CFB: 0-70m
800 mV transmit amplitude
Equalizer pathological pattern
Belden 1694A: 0-70m
Canare L-5CFB: 0-70m
800 mV transmit amplitude
Equalizer pathological pattern
–
0.25
[1]
–
UI
–
Output Rise/Fall Time
20% - 80%, HD data rate
80
120
220
ps
–
Output Rise/Fall Time
20% - 80%, SD data rate
80
120
350
ps
–
Mismatch in Rise/Fall Time
–
–
–
30
ps
–
Duty Cycle Distortion
HD color bar pattern
–
20
–
ps
–
Overshoot
–
–
–
10
%
–
Input Return Loss
–
-15
–
–
dB
–
Input Resistance
Single-ended
–
2.5
–
k
Ω
–
Input Capacitance
Single-ended
–
1
–
pF
–
Output Resistance
Single-ended
–
50
–
Ω
Notes
4. Not tested. Guaranteed by design simulations.
5. Based on characterization across temperature and voltage with 70m of Belden 1694A cable, transmitting SMPTE Equalizer Pathological Test Pattern.
6. Based on characterization across temperature and voltage with 175m of Belden 1694A cable, transmitting SMPTE Equalizer Pathological Test Pattern.
5. Based on characterization across temperature and voltage with 70m of Belden 1694A cable, transmitting SMPTE Equalizer Pathological Test Pattern.
6. Based on characterization across temperature and voltage with 175m of Belden 1694A cable, transmitting SMPTE Equalizer Pathological Test Pattern.