IBM 61Y Manual Do Utilizador
Symptom-to-FRU index
145
3-2-2
(Parallel port failed)
1.
I/O Legacy board
3-2-3
(Math coprocessor
failed)
1.
Optional processor (if installed)
2.
Processor
3.
Processor/PCI board
3-2-4
(Failure comparing
CMOS memory size against
actual)
actual)
1.
DIMM
2.
Processor/PCI board
3.
Battery
4.
I/O Legacy board
3-3-1
(Memory size
1.
DIMM
2.
Processor/PCI board
3.
Battery
3-3-2
(Critical SMBUS error
occurred)
1.
Disconnect the server power cord from outlet, wait 30
seconds and retry.
seconds and retry.
2.
I/O Legacy Board
3.
Processor/PCI Board
4.
DIMMs
5.
Memory Card
6.
DASD Backplane
7.
Power Supply
8.
Power Supply Backplane
9.
12C Cable
3-3-3
(No operational
memory in system)
1.
Install or reseat the memory modules, then power-on the
system (see “Using the Configuration/Setup Utility
program” on page 45).
system (see “Using the Configuration/Setup Utility
program” on page 45).
2.
If problem persists, restart the system 3 times.
Note:
Restarting the system three times will load default
settings.
settings.
3.
DIMMs
4.
Memory Board
5.
Processor/PCI Board
6.
I/O Legacy Board
Two Short Beeps
(Information only, the
configuration has changed)
(Information only, the
configuration has changed)
1.
Run Diagnostics
2.
Run Configuration/Setup
Three Short Beeps
1.
DIMM
2.
Processor/PCI Board
3.
I/O Legacy Board
One Continuous Beep
1.
Processor
2.
Optional Processor (if installed)
3.
Processor/PCI Board
4.
I/O Legacy Board
Beep/Symptom