IBM 61Y Manual Do Utilizador

Página de 226
 
 Symptom-to-FRU index
 145
3-2-2
  (Parallel port failed)
1.
I/O Legacy board
3-2-3
  (Math coprocessor 
failed)
1.
Optional processor (if installed)
2.
Processor
3.
Processor/PCI board
3-2-4
  (Failure comparing 
CMOS memory size against 
actual)
1.
DIMM
2.
Processor/PCI board
3.
Battery
4.
I/O Legacy board
3-3-1
 (Memory size 
mismatch occurred, see 
"Memory Settings" on page 
49)
1.
DIMM
2.
Processor/PCI board
3.
Battery
3-3-2
 (Critical SMBUS error 
occurred)
1.
Disconnect the server power cord from outlet, wait 30 
seconds and retry.
2.
I/O Legacy Board
3.
Processor/PCI Board
4.
DIMMs
5.
Memory Card
6.
DASD Backplane
7.
Power Supply
8.
Power Supply Backplane
9.
12C Cable
3-3-3  
(No operational 
memory in system)
1.
Install or reseat the memory modules, then power-on the 
system (see “Using the Configuration/Setup Utility 
program” on page 45)
2.
If problem persists, restart the system 3 times.
Note:
Restarting the system three times will load default 
settings.
3.
DIMMs
4.
Memory Board
5.
Processor/PCI Board
6.
I/O Legacy Board
Two Short Beeps 
(Information only, the 
configuration has changed)
1.
Run Diagnostics
2.
Run Configuration/Setup
Three Short Beeps
1.
DIMM
2.
Processor/PCI Board
3.
I/O Legacy Board
One Continuous Beep
1.
Processor
2.
Optional Processor  (if installed)
3.
Processor/PCI Board
4.
I/O Legacy Board
Beep/Symptom
FRU/Action