IBM 81Y Manual Do Utilizador

Página de 226
 
 Symptom-to-FRU index
 169
DASD checkout
Host Built-In Self Test (BIST) checkout
I2C bus fault messages
System shutoff due to high ambient 
temperature
 (level-critical; high ambient 
temperature)
1.
Ambient temperature must be within 
normal operating specifications 
(see 
System shutoff due to system board under 
temperature
 (level-critical; system board is 
under temperature)
1.
Ambient temperature must be within 
normal operating specifications 
(see 
Message
Action
Hard drive (SCSI ID "X") removal detected
 
(level-critical; hard drive "X" has been 
removed)
1.
Information only, take action as 
appropriate.
Hard drive (SCSI ID "X") fault
1.
Replace hard drive (SCSI ID "X").
Message
Action
Host BIST fail
 (level-informational; host’s 
built-in self test failed)
1.
Reseat CPU
2.
Reseat VRM
3.
Replace CPU
Message
Action
Failure reading I2C device.  Check devices 
on bus 0.
1.
Replace I/O Legacy Board
Failure reading I2C device.  Check devices 
on bus 1.
1.
Reseat I/O Legacy Board
2.
Reseat power supplies
3.
Replace power supply
4.
Replace Power Backplane
5.
Replace I/O Legacy Board
Message
Action