Maintenance Object Repair Procedures
Page 10-82
ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
Station Present Test (also called Ringing
Application Test) (#48)
Application Test) (#48)
This test provides a burst of ringing current to the terminal equipment and
detects that current flows. This test is to ascertain whether or not terminal
equipment is connected to the port.
detects that current flows. This test is to ascertain whether or not terminal
equipment is connected to the port.
This test may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing is disturbing the customer or the terminal equipment,
it should be disabled using the Tests field of the station administration screen.
However, on some releases of the software, this action disables Tests #6, #47,
and #35 as well as Test #48.
maintenance. If this ringing is disturbing the customer or the terminal equipment,
it should be disabled using the Tests field of the station administration screen.
However, on some releases of the software, this action disables Tests #6, #47,
and #35 as well as Test #48.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the
list
config
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board
command.
3. Issue the
reset board
command.
4. Issue the
release busy board
command.
5. Issue the
test board long
command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
dispatch to check to ensure that there is a valid board inserted.
Table 10-31.
TEST #48 Station Present Test
Error
Code
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
Continued on next page
Table 10-30.
TEST #47 Loop Around and Conference Test —
Continued
Error
Code
Code
Test
Result
Description/ Recommendation
Continued on next page