Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Routine Maintenance Procedures 
Page 5-9
Troubleshooting Control Cabinet Power Units 
5
The DEFINITY AUDIX System is now powered up. When the system 
is in the active state, the display indicates 
ADX
, and the red LED is 
off.
NOTE:
When powering up, the DEFINITY ADUXI System automatically 
reboots. This sequence may show an 
MD
 or 
MJ ADX
 alarm in the 
display until the system how powered up. When the system has 
completed its power up sequence, the display reads: 
ADX
.
Troubleshooting Control Cabinet 
Power Units
1. Check that the translation card is in the TN777B circuit pack and enter the 
save translation
 command.
2. On the Processor circuit pack in the PPN, set the EMER XFER (Emergency 
Transfer) switch to ON. This locks the system in the Transfer Mode until 
the trouble is cleared.
!
WARNING:
Electrostatic discharge can destroy or severely damage integrated 
circuits or circuit packs. Always wear the electrostatic discharge 
(ESD) wrist grounding strap when handling circuit packs. Connect 
the wrist strap to one of the metal tabs located on the lower left or 
right side of one of the carriers.
3. Unlatch the locking lever and unseat the power unit.
4. Unseat all the 
control
 circuit packs.
5. Reseat the power unit. If the yellow LED on the suspect power unit lights 
immediately, the control circuit packs can be presumed to be healthy. If 
the yellow LED on the suspect power unit does 
not
 light immediately, 
continue with the next step.
6. Reseat the circuit packs one at a time while observing the LED on the 
power unit.
a. If the yellow LED on the power unit lights when a specific circuit 
pack is reseated, unseat and reseat the same circuit pack again to 
rule out a transient problem. If the yellow LED lights again, the 
problem is with the circuit pack, and the power unit is functioning 
properly. Replace the defective circuit pack.
b. If the yellow LED on the suspect power unit does 
not
 light during 
the reseating of the control circuit packs, continue with the next 
step.
7. Unseat all 
port
 circuit packs.