BRI Port Local LAN Loop Around Test (#618)
This test is destructive
.
This test, which verifies the connectivity of a BRI port across the LAN Bus, 
executes only if the port is out-of-service. The test aborts if calls associated with 
the port are in-progress. Failures of this test indicate either on-board faults 
associated with the BRI-PORT hardware on the circuit pack or problems with the 
LAN Bus, which is used to form connectivity between the switch and the 
BRI-PORT.
The dotted lines in Figure 10-7 show how a Loop Around Test is performed 
across the Packet Bus for the D-channel.
1, 2
FAIL
The NPE of the tested port was found to be transmitting 
in error. This causes noisy and unreliable connections. 
Error code 1 indicates that the NPE Crosstalk Test failed 
on Channel B1. Error code 2 indicates that the NPE 
Crosstalk Test failed on Channel B1.
1. Replace circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, 
repeat this test a maximum of 10 times to make sure 
it continues to pass.
2. If complaints still exist, examine the station, 
connections, and wiring.