Routine Maintenance Procedures 
Page 5-25
Software Upgrade 
5
7. Enter 
list configuration software-version
, and press 
Enter
 to compare the 
version number of the Release 5.4 software program (displayed on the 
terminal) with the TN790 version number (written on a label on the TN790’s 
faceplate). If the version numbers are not the same, change the version 
number on the TN790 label so that they agree.
8. Perform a sanity check on the system running the new software by 
executing the following commands in this order:
a.
status system 1
 (to check out unusual status in the system)
b.
list station
 (to ensure that the translation is read in properly)
c.
display alarm 
(to ensure no alarm is raised in the system)
d.
list trunk-group
 (to ensure the translation is read in properly)
e.
list hunt-group
 (to ensure the translation is read in properly)
This ensures there is no translation corruption and the translations can be 
saved with the new software.
NOTE:
If the new load must be returned to the previous software load, 
re-install the TN786B/CPP1 circuit packs and reboot with the 
previous version’s translation card.
9. Get the DOSS order number of the upgrade, and call the regional CSA to 
request an “init” login. Once logged in as “init,” the CSA should assign the 
Release 5.4 option, which automatically sets the 24-hour password aging 
for the upgraded system’s customer logins. 
NOTE:
Certain forms have changed for DEFINITY ECS R5. Upgraded 
translations may appear on a different form, fields may shift within a 
form, and the name assignments to particular fields may change. 
10. Notify the switch administrator that any previous login names and 
passwords still exist, but that the passwords expire in 24 hours. The new 
login names and passwords must conform to the requirements below.
NOTE:
A password must have from 4 to 11 alphanumeric characters 
including at least 1 alphabetic character and 1 numeric character. A 
login name must have from 3 to 6 alphanumeric characters.
11. Since an R1V3.0 G3-MA cannot notify users about expiring passwords, 
disable password aging for any login name used with an R1V3.0 G3-MA.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select 
Maintenance
.