Page 10-344
CO-TRK (CO Trunk) 
10
NPE Crosstalk Test (#6)
One or more Network Processing Elements (NPEs) reside on each circuit pack 
with a TDM Bus interface. The NPE controls port connectivity and gain, and 
provides conferencing functions on a per port basis. The NPE Crosstalk Test 
verifies that this port’s NPE channel talks on the selected time slot and never 
crosses over to time slots reserved for other connections. If the NPE is not 
working correctly, one way and noisy connections may be observed. This test is 
usually only part of a port’s long test sequence and takes approximately 20 to 30 
seconds to complete.
57481
FAIL
On-board test of programmable transmission circuitry 
failed.
1. Replace the circuit pack.
PASS
This test verifies that the port is able to apply ground for 
outgoing calls and detect ground for incoming calls; 
however, it does not provide information on whether a 
CO line is actually connected. User-reported troubles on 
this port should be investigated by using other port tests 
and by examining trunk or external wiring.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are 
correct. Translate the board, if necessary.
2. Issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board
 command. This should 
re-establish the linkage between the internal ID and 
the port.