Maintenance Object Repair Procedures 
Page 10-361
CONFIG (System Configuration) 
10
CONFIG (System Configuration)
The System Configuration maintenance object (MO) oversees logical insertion 
and removal of circuit packs in the system. When Switch Control detects that a 
circuit pack is present in a port slot, it informs System Configuration and System 
Configuration queries the circuit pack to determine the type and vintage of the 
circuit pack. Similarly, when Switch Control detects that a circuit pack has been 
removed from a port slot, it informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors 
are logged to the Hardware Error Log (see below).
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error indicates that a Port circuit pack in the system did not respond 
to a circuit pack type inquiry. Follow the procedures outlined in (b) to 
determine if there is an error.
b. This error indicates that less than 25% of Trunk Group is available.
c. This error indicates that a Port circuit pack in the system did not respond 
to a vintage inquiry.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
Full Name of MO
CONFIG
none
none
System Configuration
System Configuration Error Log Entries
Error Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
none
2-117(a)
0-2
none
257(b)
none
1002-1117(c)
0-2
none