DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-459
DID-TRK (DID Trunk) 
10
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry. The battery feed circuitry is tested 
for on-/off-hook detection, battery shutdown, and battery reversal (WINK) 
capabilities.
PASS
DID Trunk Loop Around and Conference Test is 
successful. This port is functioning properly.
1. If users are reporting troubles, examine loop 
connections to the port and refer problem to the CO.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are correct. 
Translate the board, if necessary.
2. Issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board
 command. This should 
re-establish the linkage between the internal ID and the 
port.
Table 10-126.
TEST #35 Port Diagnostic Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
System resources required to run this test were not 
available.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page