Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-465
DIG-BD (Digital Line Circuit Pack)
10
DIG-BD (Digital Line Circuit Pack)
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also DIG-LINE (Digital Line) Maintenance
documentation for related line information.
circuit pack level errors. See also DIG-LINE (Digital Line) Maintenance
documentation for related line information.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the
carrier where the circuit pack is located (for example, 01, 02, ..., etc.).
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the
carrier where the circuit pack is located (for example, 01, 02, ..., etc.).
MO Name As
It Appears in
Alarm Log
Alarm
Level
Initial System
Technician
Command to Run
1
Full Name of MO
DIG-BD
MIN
test board PCSS sh
Digital Line Circuit Pack
DIG-BD
WRN
test board PCSS sh
Digital Line Circuit Pack