Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-470
DIG-LINE (Digital Line) 
10
2. 603A1/D1 Terminals
a. TN754 (4-wire, Mu-law), 
b. TN413 (4-wire, A-law)
c. TN754B (4-wire, A-law/Mu-law selectable)
Downloadable Terminal Parameters
The following parameters are downloaded to programmable terminals:
Nonvolatile Memory
Nonvolatile memory is used to store downloadable parameters in programmable 
terminals. Therefore, once the terminal has been downloaded, it is not be 
necessary to download it again, even if power is removed from the terminal.
If the nonvolatile memory fails with power still present, the terminal will revert to its 
default factory settings except for its A-law/Mu-law companding settings which 
are stored in RAM. If power is removed after the nonvolatile memory fails, the 
terminal will revert to its factory default settings.
Mu-law companding is assigned as a default setting at the factory, so, for 
domestic use, a programmable terminal can place calls even though it has not 
been downloaded from the PBX.
DOWNLOADABLE PARAMETERS
Parameter
Scope
Terminal
International Flags 
(A-law/Mu-law, Display Mode, 
DLI Voltage level)
System level
84xx, 603x, 302B1
Primary Levels 
(Transmission & Sidetone)
System level
84xx, 603x, 302B1
Adjunct Levels
(Transmission & Sidetone)
System level
84xx
Handset Expander Option
System level
84xx
Administrable Options 
(Speakerphone & Mute Button)
Per-terminal
84xx 
Administrable Softkeys
Per-terminal, 
System level
8410D, 8434D