Maintenance Object Repair Procedures 
Page 10-499
DIOD-DS1 (DS1 DIOD Trunk) 
10
Three trunk service states are specified by DS1 DIOD trunk maintenance:
Hardware Error Log Entries and Test to Clear 
Values
out-of-service
The trunk is in a deactivated state and 
cannot be used for either incoming or 
outgoing calls.
in-service
The trunk is in an activated state and can 
be used for both incoming and outgoing 
calls.
disconnect (ready-for-service)
The trunk is in an activated state but can 
only be used for an incoming call.
DS1 DIOD Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test trunk <grp>/<mbr>
1(a)
57408
1(a)
57487 
57476 
57477 
57485
15(b)
Any
Port Audit and 
Update Test (#36)
18(c)
0
busyout trunk 
<grp>/<mbr>
WARNIN
G
OFF
release trunk 
<grp>/<mbr>
130(d)
None
WARNIN
G
ON
test trunk <grp>/<mbr>
257(e)
57392
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/MAJ
2
OFF
513(f)
57393
DS1 Tie Trunk 
Seizure Test (#136)
MIN/MAJ
2
OFF
769(g)
57484
1025(h)
51200
1025
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/
WRN
3
OFF
test trunk <grp>/<mbr> 
r 2
Continued on next page