Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-502
DIOD-DS1 (DS1 DIOD Trunk) 
10
m. Error Type 2817
Glare error. This error is logged only. It is not a 
hardware failure and hence does not start any testing or generate any 
alarms. This error is the result of a simultaneous seizure of a two-way trunk 
from both the near-end and the far-end. Attempt to place the call again. If 
the error persists, execute the Dial Tone Seizure Test (#314) and follow 
those procedures.
n. Error Type 3840
Port Audit and Update Test (#36) failed due to an 
internal system error. Enter the 
status trunk
 command to verify the status 
of the trunk. If the trunk is out-of-service, then enter the 
release trunk
 
command to put it back into in-service. Retry the test command. If the test 
continues to abort, then escalate the problem.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test,
 for example, you may also clear errors generated from other tests 
in the testing sequence.
NPE Crosstalk Test (#6)
One or more Network Processing Elements (NPEs) resides on each circuit pack 
with a TDM Bus interface. (The TN464 UDS1 circuit pack has one SCOTCH-NPE 
chip instead of several NPE chips.) The NPE controls port connectivity and gain, 
and provides conferencing functions on a per-port basis. The NPE Crosstalk Test 
verifies that this port’s NPE channel talks on the selected time slot and never 
crosses over to time slots reserved for other connections. If the NPE is not 
working correctly, one-way and noisy connections may be observed. This test is 
usually only part of a port’s Long Test Sequence and takes about 20 to 30 
seconds to complete.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short 
Test 
Sequence
Long 
Test 
Sequence
D/ND
1
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
DS1 Dial Tone Test (#314)
X
X
ND
Port Audit and Update Test (#36)
X
X
ND