DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-517
DIOD-TRK (DIOD Trunk) [G1.2SE] 
10
NOTE:
At the administration terminal, busyout the affected port, and run a Long 
test. If Dial Tone Test #0 passes, ignore this error. Release the port.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test,
 for example, you may also clear errors generated from other tests 
in the testing sequence.
2817
57393
CO released the trunk at least four 
minutes after the PBX dropped the call. 
This error code is log only and causes 
no other testing to occur. No alarm is 
generated.
Check for other errors.
3073
57376
No loop current on incoming call. The 
incoming destination has already 
answered and no loop current has been 
detected. If this is a hard fault, the dial 
tone test and all outgoing calls should 
also fail.
Check for other errors.
3585
57424
No loop current on outgoing call. This 
error occurs on attempt to seize a loop 
or ground-start trunk for an outgoing 
call. An error occurs if loop current is 
not detected or the caller hangs up 
before it is detected.
See Note at end of table.
Table 10-139.
DIOD Trunk Errors with NO Tests  — 
Continued
Error
Type
Aux 
Data
Description and System Action
System Technician Action
Continued on next page