Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-610
DUPINT (Duplication Interface Circuit Pack) 
10
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates that an unexpected hardware reset has occurred on 
the Duplication Interface circuit pack. Appropriate action has been taken 
by the software to prevent malfunction. However, if this type error occurs 
with regular frequency, the DUPINT circuit pack may need to be replaced.
b. There are several possible Aux Data fields for this error, including blank. 
All indicate loss of contact with the indicated Duplication Interface circuit 
packs. The following table summarizes the Aux Data fields.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-170.
Duplication Interface Circuit Pack Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test dup 1C sh r 1
1
Sanity Circuit Test (#273)
MAJOR/ 
WRN
ON
test dup 1C l r 1
108 (a)
Any
None
109 (a)
Any
None
257
SAT Loop Back Test (#274)
MAJOR/ 
WRN
ON
test dup 1C sh r 3
513
SPE A Loop Back Test (#275)
MAJOR/ 
WRN
ON
test dup 1C sh r 3
769
SPE B Loop Back Test (#276)
MAJOR/ 
WRN
ON
test dup 1C sh r 3
1025
Sanity Maze Test (#277)
MAJOR 
/WRN
ON
test dup 1C sh r 3
1281 (b)
Any
Dupint Status Query Test (#315)
MAJOR/ 
WRN
ON
test dup 1C sh r 6
1537 (c)
Any
Background Test Query Test 
(#271)
MAJOR/ 
WRN
ON
test dup 1C sh r 3
1793 (d)
Any
MBUS Time-Out Query Test 
(#285)
MAJOR/ 
WRN
ON
test dup 1C l r 3
2049
Inter-Dupint Loop Around Test 
(#280)
MAJOR/ 
WRN
ON
test dup 1C sh r 3