Maintenance Object Repair Procedures 
Page 10-672
EXP-INTF (Expansion Interface Circuit Pack) 
10
Expansion Interface Fiber Out-of-Frame (FOOF) 
Query Test (#238)
This test is a request to an Expansion Interface circuit pack to determine if it is 
currently detecting the framing sequence on the incoming fiber data stream. If it 
cannot detect this framing signal, the Expansion Interface circuit pack is not able 
to establish a link with the opposite Expansion Interface circuit pack.
0
NO 
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 
131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, 
check for hyperactivity (error 1538). If hyperactive, use the 
reset 
board PCSS 
command.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 10-192.
TEST #238 EI Fiber Out-of-Frame Query Test 
Error 
Code
Test 
Result
Description/Recommendation
ABORT
Internal system error
2000
ABORT
Response to the test request was not received within the allowable 
time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2026
ABORT
Expansion Interface circuit pack responded with an unknown reply.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-191.
TEST #237 EI Neighbor Query Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation
Continued on next page