Maintenance Object Repair Procedures
Page 10-802
ISDN-SGR (ISDN-PRI Signaling Group)
10
Error Log Entries and Test to Clear Values
Notes:
a. This switch sent a message to the far-end switch or terminal adapter, and
the far-end did not respond in the allotted time. Possible causes include
link failure and congestion or outage at the far-end. The Aux Data field
contains Layer 3 protocol information used by internal counters.
link failure and congestion or outage at the far-end. The Aux Data field
contains Layer 3 protocol information used by internal counters.
1.
Run the Short or Long Test Sequence. Refer to the appropriate test description and follow the
recommended procedures.
recommended procedures.
Table 10-222.
ISDN-PRI Signaling Group Error Log Entries
Error
Codes
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
test sig-group
<group>
<group>
1 (a)
Any
none
257 (b)
Any
none
test sig-group
<group>
<group>
513 (c)
Any
none
test sig-group
<group>
<group>
769
Any
Primary Signaling
Link Hardware
Check (#636)
Link Hardware
Check (#636)
test sig-group
<group>
<group>
1025
Any
Secondary
Signaling Link
Hardware Check
(#639)
Signaling Link
Hardware Check
(#639)
test sig-group
<group>
<group>
1793 (d)
Any
Layer 2 Status
(Test #647)
(Test #647)
WARNING
OFF
test sig-group
<group>
<group>
2049 (e)
Any
Layer 2 Status
(Test #647)
(Test #647)
WARNING
OFF
test sig-group
<group>
<group>
2305 (f)
Any
Remote Layer 3
Query (Test #637)
Query (Test #637)
MINOR
OFF
test sig-group
<group>
<group>
3585 (g)
port
number
number
none
none
3840-
3928 (h)
3928 (h)
port
number
number
none