DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-871
MEM-BD (Memory) 
10
c. This test is run only on the Standby SPE in a High or Critical Reliability 
system. On other systems or on the Active SPE, the test is run only via a 
reset system 4
 command or a 
reset system 5
 command.
Read All Memory Test (#85)
This test is a nondestructive test. The test reads every memory location in 
memory and writes it back. A failure of this test indicates a failure in the 
Processor or Memory circuit pack.
Text Checksum Test (#86)
This test is a nondestructive test. The test computes the checksum of the 
DEFINITY software text module, and it validates the operation of the flash ROM. A 
failure of this test indicates corruption of the Text.
Table 10-249.
TEST #85 Read All Memory Test 
Error 
Code
Test 
Result
Description/Recommendation 
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
1
FAIL
If the system can still provide service, this indicates that the Processor 
circuit pack or Memory has a problem, but can still function. The error code 
"1" indicates that MEM-BD 1 is failing the test.
1. Replace the PROCR (Processor circuit pack).
!
WARNING:
If the Processor circuit pack must be replaced, and if there is a blank 
in the Expansion Memory circuit pack slot (that is, in the slot 
immediately to the right of the Processor circuit pack), remove the 
blank before removing the circuit pack. Otherwise, the circuit pack 
and/or the two connectors that are used to connect the Expansion 
Memory circuit pack (if available) might become damaged.
PASS
The Memory is healthy.
Continued on next page