DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-878
MET-LINE (MET Line) 
10
In Service—Once the system receives a message from the voice terminal 
communicating that it is present, the station is put into the in-service state. 
The terminal can also be forced into the in-service state if it goes off-hook 
while it is in the ready-for-service state.
When the 
status station
 command has been run, and the status screen 
appears, the status is reported as either out-of-service, in-service (as stated in 
the preceding list), or disconnect (the station is in the ready-for-service state).
Hardware Error Log Entries and Test to Clear 
Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2.
Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the 
set options
 command.
MET Line Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
40987
None
18 (b)
0
busyout port 
PCSSpp
WARNING
OFF
release port PCSSpp
130 (c)
None
WARNING
ON
test port PCSSpp sh
257 (d)
40988
None
MIN/WRN
2
OFF
513 (e)
40965
Hybrid Line Station 
Audits Test (#61)
WARNING
OFF
test port PCSSpp sh r 4
769
Port Diagnostic 
Test (#35)
MIN/WRN
ON
test port PCSSpp l r 3
1025
Hybrid & Conf. 
Circuits Test (#57)
MIN/WRN
ON
test port PCSSpp l r 3
1537 (f)
40968
None
MIN/WRN
OFF
1793
TDMNPE Crosstalk 
Test (#6)
MIN/WRN
ON
test port PCSSpp l r 3
2049(g)
32770
2049(h)
40967
3840(i)
40989