Maintenance Object Repair Procedures 
Page 10-922
MODEM-PT (Modem Pool Port) 
10
Modem Pool Conversion Resource Loop Around 
Test (#98)
The Modem Pool Conversion Resource Loop Around Test is set up as follows:
NONE
FAIL
The test failed. This error is internal to the Pooled 
Modem circuit pack and does not involve external 
equipment or interfaces.
1. Busyout both of the TN758 Pooled Modem 
conversion resources on the circuit pack containing 
the failing conversion resource.
2. If the test continues to fail, replace the Pooled 
Modem circuit pack and retest.
3. If the circuit pack fails after replacement, escalate 
the problem.
ANY
FAIL
The Network Processing Element (NPE) of the tested 
port did not conference the tones correctly. This causes 
noisy and unreliable connections.
1. If the remaining ports are currently not in use (that is, 
yellow LED is off), attempt to reset the circuit pack. 
Then repeat the test.
2. If the test fails again, replace the circuit pack.
PASS
The port can correctly conference multiple connections. 
User-reported troubles on this port should be 
investigated using other port tests and by examining 
station, trunk, or external wiring.
Table 10-261.
TEST #97 Modem Pool Conference Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page