DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1025
PE-BCHL (PRI Endpoint Port) 
10
PE-BCHL (PRI Endpoint Port)
A PRI Endpoint provides ISDN-PRI (Primary Rate Interface) connections for 
customers with application equipment or terminal adapters that terminate 
ISDN-PRI. The equipment or terminal adapters are connected to the switch via 
the UDS1 interface circuit pack. PRI Endpoint Port (PE-BCHL) maintenance 
provides a strategy to maintain PRI Endpoint Port hardware circuitry on the UDS1 
circuit pack. The maintenance strategy involves logging PRI Endpoint Port 
hardware errors, running tests for port initialization, periodic and scheduled 
maintenance, system technician-demanded tests, and alarm escalation and 
resolution.
Wideband Switching
The Wideband Switching capability supports end-to-end connectivity between 
customer endpoints at data rates from 128 to 1536 kbps over T1 facilities and to 
1984 kbps over E1 facilities. DEFINITY switching capabilities are extended to 
support wideband calls comprised of multiple DS0s that are switched end-to-end 
as a single entity.
The Wideband Switching capability is designed for ISDN application equipment 
(for example, ISDN video codecs), but it retains provisions for non-ISDN 
application equipment by using PRI terminal adapters. In the same sense that a 
DEFINITY data module acts as a DCP or BRI terminal adapter between endpoint 
data (for example, V.35) and dialing (for example, RS-366) interfaces and a DCP 
interface, a PRI terminal adapter acts as a wideband terminal adapter between 
endpoint data and dialing interfaces and DEFINITY’s line-side ISDN PRI 
interface.
The Wideband Switching Capability introduces PRI Endpoints on DEFINITY 
line-side interfaces. A PRI Endpoint consists of one or more contiguous 
B-channels on a line-side T1 or E1 ISDN PRI facility, and it has an extension 
number. Endpoints initiate and receive calls using ISDN SETUP messages that 
indicate the data rate and specific B-channels to be used, and they 
communicate all other call status information via standard ISDN messages. Any 
1.
For additional repair information, see also UDS1-BD (UDS1 Interface Circuit Pack) 
maintenance documentation and 
 in 
.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
PE-BCHL
1
MINOR
test port PCSSpp l
PRI Endpoint Port
PE-BCHL
WARNING
test port PCSSpp sh
PRI Endpoint Port