Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1033
PE-BCHL (PRI Endpoint Port) 
10
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates a disagreement between the switch and the 
terminal adapter at the other end of the connection with regard to the 
ISDN 
call
 state of the PRI Endpoint Port. This switch automatically tries to 
recover by clearing the call (that is, the call is torn down). The 
status 
pri-endpoint <extension>
 command can be used to determine the state 
of the port.
When running the Short Test Sequence of tests, pay close attention to the 
results of the Call State Audit Test (#257).
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-294.
PRI Endpoint Port Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
test port PCSSpp sh r 1
15 (b)
Any
Audit and Update 
Test (#36)
18 (c)
0
busyout pri-endpoint 
<extension> busyout 
port <PCSSpp>
WARNING
OFF
release pri-endpoint 
<extension> release port 
<PCSSpp>
129 (d)
None
WARNING
OFF
test port PCSSpp sh r 1
130 (e)
None
WARNING
ON
test port PCSSpp sh
257 (f)
Any
None
test port PCSSpp sh r 1
513 (g)
Any
None
WARNING
OFF
test port PCSSpp sh r 1
76 9 (f)
Any
None
test port PCSSpp sh r 1
1281 (h)
Any
Conference Circuit 
Test (#7)
MINOR
ON
test port PCSSpp l r 4
1537 (i)
Any
NPE Crosstalk Test 
(#6)
MINOR
ON
test port PCSSpp l r 3
1793 (j)
Any
None
test port PCSSpp sh r 1
3073 (k)
Any
Service State Audit 
(#256)
test port PCSSpp sh r 2
3585 (l)
Any
None
None
Continued on next page