Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1039
PE-BCHL (PRI Endpoint Port) 
10
Audit and Update Test (#36)
This test sends port level translation data from the switch processor to the UDS1 
interface circuit pack to ensure that the port’s translation is correct. The port audit 
operation verifies the consistency of the current state of the port that is kept in the 
UDS1 interface circuit pack and in the switch software.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This 
causes noisy and unreliable connections.
1. Replace the circuit pack. Even though wideband calls do not use the 
conferencing feature on the NPE, this failure indicates problems with 
the circuit pack hardware.
PASS
The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated by using the other port tests 
and by examining the terminal adapter or the external wiring.
Table 10-298.
TEST #36 Audit and Update Test 
Error 
Code
Test 
Result
Description/Recommendation 
ABORT
Internal system error
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The test failed due to Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-297.
TEST #7 Conference Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation 
Continued on next page