DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1067
PI-LINK (Processor Interface Link) 
10
ISDN Hardware Check Test (#234)
This test checks the status of the ISDN hardware which is the DS1 Interface 
circuit pack and cabling. Status of the DS1 port is kept by the system. The state 
of the port can be in-service or out-of-service. This state is updated by DS1 
Interface circuit pack maintenance. If DS1 maintenance detects a problem with 
the physical medium near-end or far-end, the Processor Interface Link 
maintenance is instructed to restart the link. Therefore, if this test fails, the port is 
considered out-of-service and the link cannot be brought up until DS1 
maintenance changes the state to in-service. This is more of a status inquiry than 
a test. Thus, the only recovery procedure is to refer to DS1-BD (DS1 Trunk Circuit 
Pack) Maintenance documentation.
PASS
PI-LINK currently does not have any of the above errors.
Table 10-308.
TEST #234 ISDN Hardware Check Test 
Error 
Code
Test 
Result
Description/Recommendation 
ABORT
Internal system error
1. Retry the test at 1-minute intervals a maximum of 5 times.
1005
ABORT
This test only runs for ISDN-PRI links. This link is a BX.25 link and, thus, 
aborts.
FAIL
Indicates that there is a physical problem with the DS1 facility link.
1. Cross-reference DS1 Interface circuit pack errors for possible reason. 
Refer to “DS1-BD”.
2. Retry the test. It continues to fail until the DS1 problem is cleared up.
PASS
DS1 facility is functioning correctly.
Continued on next page
Table 10-307.
TEST #233 Link Quality Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation 
Continued on next page