Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1071
PI-PT (Processor Interface Port) 
10
Standby Processor Interface Port Test (#404)
This test is the same as Test #182 in the Processor Interface Link (PI-LINK) 
Maintenance documentation. However, this test only runs on the Standby 
Processor Interface circuit pack. It is an on-board loop around test. This test 
checks the health of physical port on the circuit pack. If the test fails, then a Major 
alarm is raised on the circuit pack. When the circuit pack is put into local loop 
around mode, frames are looped internally on the circuit pack. If the test fails, the 
Processor Interface circuit pack reports the failure. It is a good check of most of 
the working hardware on the Processor Interface circuit pack.
Table 10-312.
TEST #404 Standby Processor Interface Port Test 
Error 
Code
Test 
Result
Description/Recommendation 
2
9
16
80
84
85
93
94
102
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1124
ABORT
The PI link for this port is currently disabled. This test does not run on 
disabled PI links.
1. Retry this test if the PI link is re-enabled. Enter the 
display 
communication-interface link
 command to verify that this link has 
been disabled.
1125
ABORT
The Processor Interface Loop Around Test on this port could not be 
executed since the Processor Interface circuit pack is not in the correct 
state.
1. Check PI-BD for possible errors and resolve them first.
2. Rerun the 
test interface PCS sh
 command.
3. If the test continues to abort while the PI-BD Test (#423) passes, 
escalate the problem.
Continued on next page