Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1081
PKT-BUS (Packet Bus) 
10
PKT-BUS (Packet Bus) 
The Packet Bus consists of a single bus, and one such bus appears in each port 
network. The Packet Bus in each port network is physically independent. 
Therefore, there is one instance of the Packet Bus maintenance object for each 
port network.
In DEFINITY, the Packet Bus is used to carry ISDN-BRI and ASAI signaling 
information. The SPE interface to the Packet Bus is in the TN778 Packet Control 
circuit pack (PKT-CTRL). Packet Bus maintenance is performed only when the 
Packet Bus is enabled on the Maintenance-Related System Parameters form. 
Packet Bus testing is dependent on the Packet Bus port of the TN771 
Maintenance/Test circuit pack, the TN778 Packet Control Circuit Pack 
(PKT-CTRL), the TN570 Expansion Interface circuit pack (EXP-INTF), and on the 
ISDN-BRI circuit packs (BRI-BD). Packet Bus tests may abort if some of this 
hardware is not present in the system. Also, these tests may yield inconsistent 
results if some of this hardware is defective.
The interactions between the Packet Bus and the circuit packs that use the bus 
are complex. For this reason, the Packet Bus can be alarmed due to a circuit 
pack failure and, conversely, circuit packs can be alarmed due to a Packet Bus 
failure
 describes Packet 
Bus maintenance and also the interactions of the bus with the Packet circuit 
packs. The chapter discusses fault isolation and correction procedures, and it 
should be referenced for all procedures and required decisions. The "Packet Bus 
Fault Isolation Flowchart" section of Chapter 9 is the normal starting point in the 
chapter for experienced technicians. However, technicians who are unfamiliar 
with the Packet Bus and its use should refer to the introductory material. This 
section on PKT-BUS is limited to a description of the Error and Alarm Log entries 
for the Packet Bus maintenance object and to a description of the Packet Bus 
test sequence.
A failure of one or more circuit packs that use the Packet Bus can cause a Packet 
Bus alarm. In addition, a Packet Bus failure can cause loss of service to one or 
more such circuit packs, as well as to the ports and endpoints associated with 
the ISDN-BRI circuit pack (BRI-PORT, ABRI-PORT, BRI-SET, BRI-DAT, and 
1.
Where P is an appropriate port network number determined from the PORT field on the Alarm 
or Error Log.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
Full Name of MO
PKT-BUS
MAJOR
test pkt P l r 2
Packet Bus
PKT-BUS
MINOR
test pkt P l
Packet Bus
PKT-BUS
WARNING
test pkt P l
Packet Bus