Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1124
POWER (Battery & Battery Charger) for AC-Powered Systems
10
5. Check the battery dates and replace the batteries if they are more than
four years old or if a POWER alarm is present.
NOTE:
If any defective batteries are found, replace all of them. Batteries are
ordered in sets of three and should be replaced as such.
ordered in sets of three and should be replaced as such.
6. If no defective batteries are found, replace the entire charger.
7. Close the cover and secure it with the screw.
8. Reconnect the cord and move the power switch to ON.
Hardware Error Log Entries and Test to Clear
Values
Values
a. Where P is an appropriate port network number determined via the Port
field from the Alarm or Error Log.
System Technician-Demanded Tests:
Descriptions and Error Codes
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
inspecting errors in the system. By clearing error codes associated with the
Battery & Battery Charger Query Test,
for example, you may also clear errors
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
Battery & Battery Charger Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test environment P sh r 1
1
Any
Battery & Battery
Charger Query Test
(#5) (Error Code 8)
Charger Query Test
(#5) (Error Code 8)
MINOR
ON
test environment P sh r 1
257
Any
Battery & Battery
Charger Query Test
(#5) (Error Code 4)
Charger Query Test
(#5) (Error Code 4)
MINOR
ON
test environment P sh r 1
769
Any
Battery & Battery
Charger Query Test
(#5) (Error Code 2)
Charger Query Test
(#5) (Error Code 2)
MINOR
ON
test environment P sh r 1
3840
1005
or
1028
or
1028
Battery & Battery
Charger Query Test
(#5)
Charger Query Test
(#5)
ON
test environment P sh r 1