DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Reliability Systems: A Maintenance Aid 
Page 6-32
Blocking Standby SPE Maintenance Activities for System Testing 
6
Blocking Standby SPE Maintenance
Activities for System Testing
Sometimes it is necessary to block Standby SPE maintenance activities so that 
system technician commands that test Standby SPE components can be 
conducted without being blocked with the G3MT terminal message line “Standby 
SPE busy with another task; for information use ‘status system’.” To block 
Standby SPE maintenance activities, perform the steps listed below.
!
WARNING:
The following procedure involves throwing the SPE Select Switches to 
hard-select the current Active SPE. After completing the circuit pack 
replacement procedure, verify that the SPE Select Switches have been 
returned to the AUTO position both by noting their position and by noting 
that the SPE Select Switch LEDs on the TN772 Duplication Interface circuit 
packs are not on.
1. Throw the SPE Select Switches (on the TN772 Duplication Interface circuit 
packs) to force selection of the current Active SPE. If SPE-B is currently 
the Active SPE, throw both SPE Select Switches to the right. If SPE-A is 
currently the Active SPE, throw both SPE Select Switches to the left.
2. Issue the 
status system 1st-cabinet 
command from the G3MT terminal. 
The status system form indicates the presence of MAJOR and MINOR 
alarms on both SPEs. If SPE alarm counts are displayed, run component 
tests to resolve these alarms. Allowed tests include test spe-standby, test 
duplication-interface, and test shadow-link. Use the next step if the 
allowed test commands are not accepted, otherwise skip the next step.
!
CAUTION:
If the Duplication Interface circuit pack is being tested, Test #278 
fails because the SPE Select Switches are thrown.
3. Issue the busyout spe-standby command followed by the release 
spe-standby command to force the Standby SPE into a mode to accept 
the 
test commands 
attempted in the previous step. Wait 5 minutes for the 
Standby SPE to initialize and issue the status system 1st-cabinet 
command. If the Standby SPE failed to initialize if the Standby SPE Mode 
is down. If the Standby SPE Mode is 
maint/init
 or maint/entering, execute 
the busyout spe-standby and release spe-standby command up to 2 more 
times. If this step does not succeed, try this procedure again.
4. Move each SPE Select Switch back to the AUTO position.
!
WARNING:
Move only one SPE Select Switch at a time. DO NOT move both 
switches at the same time.