Maintenance Object Repair Procedures 
Page 10-1163
PR-MAINT (Maintenance Processor) 
10
MTP Sanity Handshake Test (#106)
This test is a nondestructive test. The MTP Sanity Handshake Test is simply a 
query from a maintenance process to the MTP. The MTP must reply for the test to 
pass.
MTP Auxiliary Loop Around Test (#229)
This test is a nondestructive test. The test places the Auxiliary channel of the MTP 
into a loop around mode, and it verifies the data integrity of the channel. The 
Auxiliary channel is used as the CDR output port.
Table 10-349.
TEST #106 MTP Sanity Handshake Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
1000
ABORT
System software resources required to run this test are not available.
2033
ABORT
 Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The MTP did not respond to the Sanity Handshake Query.
1. Re-enter command with the "long" option.
2. If the test continues to fail, replace the Processor circuit pack.
PASS
The MTP responded to the Sanity Handshake Query.