Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1166
PR-MEM (TN790 RISC Memory)
10
Error Log Entries and Test to Clear Values
Notes:
a. This error (3) indicates that a software patch has been applied and either
the software patch is bad or was installed incorrectly.
1.Back out the software patch and run the
test memory UUCS long
command to verify that the problem has been cleared.
2.If the PBX system is equipped with High Reliability or Critical Reliability
option (i.e. with duplicated SPEs), and this error occurs, a SPE
interchange will occur if the health of the standby SPE permits the
interchange.
interchange will occur if the health of the standby SPE permits the
interchange.
b. The following Aux Data indicate SIMM Failures
1.SIMM A
2.SIMM B
3.SIMM A & SIMM B
4.SIMM C
5.SIMM A & SIMM C
6.SIMM B & SIMM C
7.SIMM A, SIMM B, & SIMM C
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
Table 10-351.
Memory Error Log Entries
Error
Type
Type
Aux Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test memory a/b l r 1
1
Any
Flash Memory
Checksum Test (#86)
Checksum Test (#86)
MAJOR
ON
test memory a/b l r 5
3(a)
Any
Flash Memory
Checksum Test (#86)
Checksum Test (#86)
MAJOR
ON
test memory a/b l r 5
1025
Any
Memory Parity Error
Detection Test (#87)
Detection Test (#87)
MINOR
ON
test memory a/b r 3
1281
Any
Memory Burst Read
Test (#908)
Test (#908)
MAJOR
ON
test memory a/b l r 2
1793
Any (b)(c)
Read All Memory (#85)
MAJOR
ON
test memory a/b l r 1
2049(d)
Any (b)(c)
Memory Functional
Test (#332)
Test (#332)
MAJOR
ON
test memory a/b l r 1