Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1179
PRI-CDR/SEC-CDR (PRI-CDR Link) 
10
Link Retry Test (#215)
This test sends a message to the CDR software process to make a data call to 
the extension where the CDR output device connects to or opens the EIA port to 
the CDR output device. If the CDR link is already up, this test is passed without 
making any data call or opening the EIA port.
Table 10-358.
TEST #213 Link Tear Down Test 
Error 
Code
Test 
Result
Description/ Recommendation
40
ABORT
Internal system error
50
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1010
ABORT
The CDR link has been busied out to out-of-service.
1. Enter the 
release cdr-link primary|secondary
 command to release 
the CDR link from busyout state.
2. Retry the 
test cdr-link primary|secondary long
 command to execute 
the test.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The CDR link is torn down.
Continued on next page
Table 10-359.
TEST #215 Link Retry Test 
Error 
Code
Test 
Result
Description/ Recommendation
10
ABORT
Internal system error
20
ABORT
Internal system error. Internal error in Maintenance Action Process (MAP). 
MAP returns an error back to maintenance script (HMM). Timer expires 
while waiting for the reply from MAP.
1. Retry the command at 1-minute intervals a maximum of 5 times.
30
ABORT
Internal system error
1. Refer to 
Continued on next page