Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1184
PROCR (Processor Circuit Pack) 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when you are 
inspecting errors in the system. By clearing error codes associated with the 
Processor Non-maskable Interrupt Test,
 for example, you may also clear errors 
generated from other tests in the testing sequence.
Notes:
a. Refer to PR-MAINT (Maintenance/Tape Processor) Maintenance 
documentation for a description of these tests.
b. Refer to MEMORY [386 systems only] Maintenance documentation for a 
description of these tests.
Processor Software Initiated Interrupt Test (#77)
This test is a nondestructive test. The test verifies if the 80286/386 Processor can 
exercise the three types of software-initiated interrupts:
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Processor Non-maskable Interrupt Test (#82)
X
X
ND
Processor ROM Checksum Test (#80)
X
X
ND
Processor Software Initiated Interrupt Test (#77)
X
X
ND
Processor Sanity Timer Test (#83)
X
D
MTP Outpulse Relay Test (#102) (a)
X
X
ND
MTP Analog Loop Around Test (#103) (a)
X
X
ND
MTP Sanity Handshake Test (#106) (a)
X
X
ND
MTPSAT Loop Around Test (#228) (a)
X
X
ND
MTP Aux Loop Around Test (#229) (a)
X
X
ND
MTP Reset Test (#101) (a)
X
D
MTP Dual Port Ram Test (#104) (a)
X
D
Read All Memory Test (#85)(b)
X
ND
Memory Error Detection Test (#87)(b)
X
X
ND
Text Checksum Test (#86)(b)
X
ND
Memory Functional Test (#332) (c)(b)
X
D
Memory Board Check Test (#631) (b)
X
X
ND