DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1187
PROCR (Processor Circuit Pack) 
10
Processor Sanity Timer Test (#83)
This test is destructive.
Table 10-364.
TEST #82 Processor Non-maskable Interrupt Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
FAIL
The interrupt was not detected or acted upon.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, the Processor circuit pack should be 
replaced.
!
WARNING:
If the TN786B circuit pack [386 systems only] must be replaced, and if 
there is a blank in the Expansion Memory circuit pack slot (that is, in 
the slot immediately to the right of the TN786B circuit pack), remove 
the blank before removing the circuit pack. Otherwise, the circuit pack 
and/or the two connectors that are used to connect the Expansion 
Memory circuit pack (if available) might become damaged.
3. If replacement of the Processor circuit pack still results in test failure, the 
following circuit packs should be replaced, one at a time in the order 
provided: TN770 Memory [G3iV1.1-286 only] Expansion Memory 
[G3iV2-386 only] TN765 Processor Interface, TN777B Network Control, 
TN778 Packet Control, and TN772 Duplication Interface circuit packs. 
The test should then be repeated.
4. If the test still fails after you replace all the circuit packs discussed in the 
previous step, the problem must be in the control carrier, and the carrier 
should be replaced.
PASS
The interrupt was correctly detected. The 80286/386 CPU chip is functioning 
correctly.
Continued on next page