Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1197
RING-GEN (Analog Ring Generator) 
10
RING-GEN (Analog Ring Generator)
All analog phones in DEFINITY Generic 1 cabinets must be provided with a 
voltage that allows them to ring. The Analog Ring Generator MO represents the 
device that provides the ringing voltage for analog phones in a multicarrier or 
single carrier cabinet system. In a multicarrier cabinet system, the Analog Ring 
Generator resides in the PDU. 
 shows the position of the PDU and 
illustrates that fuse F9 is used for the Analog Ring Generator. 
 shows 
the position of the fuses on the PDU and describes how to replace a fuse. In a 
single carrier cabinet system, the Analog Ring Generator is part of the WP-91153 
power unit, and each carrier in the single carrier cabinet contains its own Analog 
Ring Generator. A ringing voltage generator failure means that no ringing will 
occur on analog phones; however, ringing on digital and hybrid phones will still 
occur. 
The ringing voltage is monitored by the Tone-Clock circuit pack. In a port 
network with duplicated Tone-Clocks, it is the active Tone-Clock that performs 
this function. In an EPN made up of single-carrier cabinets, the Tone-Clock 
monitors only the ringing voltage in the carrier that contains the tone clock.
Also, if the TN2182 Tone-Clock is installed in the Processor Interface slot, the 
ringing voltage is not monitored.
The TN2036 Voltage Range circuit pack provides easy access for testing the 
various voltages on the backplane pins. 
1.
Where P is an appropriate port network number determined via the Port field from the 
Alarm or Error Log.
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System Technician 
Command to Run
1
Full Name of MO
RING-GEN
MAJOR
test environment P
Analog Ring Generator