LED Interpretation 
Page 7-5
Attendant Console LEDs 
7
Attendant Console LEDs
The console has two red LEDs, labeled ALM and ACK, on the left side of the dial. 
The left LED lights steadily when there is a Major or Minor alarm at the switch 
cabinet. The right LED lights steadily if the alarm has been successfully reported 
to INADS. If the system is unable to report the alarm to INADS, the LED flashes; 
signaling the attendant to call INADS and report the alarm.
Cabinet Power Unit LEDs
For a description of Cabinet Power Unit LEDs, refer to “AC-POWER” for 
AC-Powered Systems and “DC-POWER” for DC-Powered Systems in 
Power Distribution Unit LEDs
For a description of Power Distribution LEDs, refer to “AC-POWER” for 
AC-Powered Systems and “DC-POWER” for DC-Powered Systems in 
Control and Port Circuit Pack Status 
LEDs
Each circuit pack has three LEDs on the front panel visible at the front of the 
carrier. On all circuit packs, except the TN736 Power Unit, the LEDs indicate:
1. Red (alarm) 
— 
If the circuit pack is communicating with the system, the 
system has detected a fault in this circuit pack. An on-board alarm for this 
circuit pack is displayed in the Alarm Log.
The circuit pack also lights this LED when either the circuit pack has not 
yet initialized communication with the system or when the circuit pack 
loses contact with the system and stops functioning (circuit pack is said to 
be ‘‘in reset’’). In these cases, there may not be an alarm in the Alarm Log. 
To determine if the red LED is lit because the circuit pack is not in contact 
with the system, issue the 
list configuration board PCSS
 command, 
where PCSS refers to the slot containing this circuit pack. If the system 
does not detect the circuit pack, this command returns ‘‘Identifier not 
assigned’’ or ‘‘no board.’’
If the circuit pack has just been inserted, the system may still be initializing 
the circuit pack. If, after 5 minutes, the circuit pack still has not initialized 
communications with the system, check the MO for any special 
instructions (for example, EPN Maintenance circuit pack can stop 
EXP-INTF circuit pack from initializing). If the MO does not provide the 
needed information, perform the following steps: