Maintenance Object Repair Procedures 
Page 10-1225
S-SYN-PT (Speech Synthesis Port) 
10
Speech Synthesis Parameter Update Test (#169)
This test updates the DTMF interdigit time-out parameter used by the Speech 
Synthesis circuit pack to be consistent with that specified by the switch 
processing element (SPE).
Table 10-382.
TEST #169 Speech Synthesis Parameter Update Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources required to run this test are not 
available. The port may be busy with a valid call and 
therefore unavailable for certain tests. You must wait 
until the port is idle (yellow LED if off) before retesting.
1. If the port is idle, retry the command at one-minute 
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2100
ABORT
Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
An internal system error has occurred.
1. If the test continues to fail, escalate the problem.
PASS
The DTMF interdigit time-out parameter has been 
updated.
1. User-reported troubles should be investigated using 
other tests and by verifying that other ports on this 
circuit pack are working correctly.
Continued on next page