STBY-SPE (Standby SPE) 
10
In certain circumstances, the Standby SPE is put into Maintenance Mode by the 
Active SPE. In this mode, the SW-CTL and PKT-CTRL on the Standby SPE are still 
isolated from the TDM Bus and Packet Bus, memory shadowing is disabled, and 
its processor is no longer held in a reset state. Data Channels on the standby 
SPE Network Control circuit pack can access the TDM bus, and the maintenance 
testing can be executed in this maintenance mode. The 12 volt power supply on 
the standby SPE Network Control circuit pack can also be turned on for Memory 
Card maintenance testing. In Maintenance Mode, the Standby SPE accepts 
maintenance activity requests from the Active SPE to perform testing on Standby 
SPE components. For many of the requested activities, maintenance software on 
the Standby SPE is restarted in order to conduct the activity. Translation saves 
and announcement saves may be performed on the Standby SPE when it is in 
Maintenance Mode. While in Maintenance Mode, the Standby SPE is not as 
readily available to assume the role of the Active SPE, but it may do so 
depending upon the severity of the Active SPE fault(s).
Whenever the Standby SPE is returned to Standby Mode from Maintenance 
Mode, its DRAM Memory is refreshed. This means that the Active SPE DRAM 
Memory is shadowed over to Standby SPE DRAM Memory. The flash ROM 
memory in the Standby SPE is not refreshed, and the shadowing circuit cannot 
write data into the flash ROM memory. The refresh is necessary because, while in 
Maintenance Mode, memory shadowing to the Standby SPE is disabled and 
Standby SPE Memory is not updated to reflect changes in Active SPE Memory. 
After the refresh, Standby SPE Memory once again is an up-to-date reflection of 
Active SPE Memory.
The Standby SPE goes into Down Mode whenever certain error conditions are 
detected. These error conditions are described in detail in the "Hardware Error 
Log Entries and Test to Clear Values" section. Once the error condition(s) that 
cause(s) the Standby SPE to go into Down Mode are corrected, the Standby SPE 
is first put into Maintenance Mode to conduct testing on Standby SPE 
components. It is then returned to Standby Mode.
The current mode of the Standby SPE can be determined by issuing the 
status 
system
 command.
Components in Standby SPE Complex
The Standby SPE maintenance object is actually a composite of all the circuit 
packs in the Standby SPE. 
The TN778 Packet Control circuit pack, the TN765 Processor Interface circuit 
pack(s), and the TN772 Duplication Interface circuit pack are used.
!
WARNING:
Verify that there is an identical set of SPE complex circuit packs in each 
SPE. For example, there should be the same number of Memory circuit 
pack(s) in each SPE. If there are Processor Interface circuit pack(s) (one or