DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1268
STBY-SPE (Standby SPE) 
10
The software card-mem should be replaced by one that has a good 
checksum. The 
upgrade software
 command should be re-executed.
y. Whenever an SPE interchange is forced by using the 
health-override
 
option as part of the 
reset system interchange
 command, a WARNING 
OFF circuit pack STBY-SPE alarm is raised, and the Fault Severity Level 
(FSL) of the new standby SPE is raised to its highest possible value to 
prevent an SPE interchange back to the original active SPE. This artificial 
FSL lasts one hour or until a 
busyout spe-standby
 command is executed, 
followed by a 
release spe-standby
 command. After this time, the FSL of 
the two SPEs are recomputed, and the healthiest SPE becomes or 
remains active.
z. The system interchanged from the active SPE to the standby SPE with a 
restart that is more disruptive to service than the normal system hot start. 
The switches were not used to force this interchange. The level of restart 
can be observed by using the 
display initcauses
 command. Look for 
other alarms on the standby SPE that possibly caused this interchange. 
Also see "Reset System Interchange (High or Critical Reliability Systems 
Only)" in 
.
aa. The software vintage in the Standby SPE does not match the software 
vintage in the active SPE.
The
 upgrade software 
command
 
should be executed for the standby 
SPE as described in 
.
System Technician-Demanded Tests
The following commands can be used to test and manipulate part or all of the 
standby SPE:
busyout spe-standby
 
The 
busyout spe-standby
 command is used to stop all standby 
maintenance activity, disable shadowing, and hold the standby processor 
reset. A warning off circuit pack alarm is also raised against STBY-SPE 
MO. This command is more powerful than the 
refresh spe-standby
 
command because it preempts the standby and enters maintenance 
mode, where as the 
refresh spe-standby
 does not do this.
release spe-standby
 
The 
release spe-standby
 command is used to remove the busyout 
condition, restore memory shadowing, and force a refresh. 1 minute after 
the command is executed, the equivalent of standby scheduled 
maintenance is run.
refresh spe-standby
 
The 
refresh spe-standby
 command is used to put the Standby SPE 
immediately into Standby Mode. The command conducts the same 
activities regardless of whether the Standby SPE is already in Standby