Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1337
SYS-PRNT (System Printer) 
10
SYS-PRNT (System Printer)
The Report Scheduler feature provides the capability to schedule selected 
administration commands to be printed by an asynchronous System Printer 
(SYS-PRNT) or sent to a Personal Computer (PC). The System Printer Link to this 
external device can be administered either as a data extension or to the EIA port 
on the switch Processor (PROCR) circuit pack which provides a standard EIA 
232C interface.
System Printer Link Maintenance provides a strategy for maintaining the link 
between the system and an external SYS-PRNT output device. The strategy 
includes a set of tests for detection of errors during normal operation, 
troubleshooting actions, and alarms for serious problems. System Printer Link 
Maintenance uses a try-and-wait mechanism for maintaining the SYS-PRNT link. 
If the link set-up fails, a minor alarm is raised for service attention. A warning 
alarm is raised when the SPE has been busied out. A maximum of two link retry 
attempts is made. After the second attempt, set-up attempts are only made by 
the application software (that is, the 15-minute timer fires and jobs are printed 
unless an immediate job was entered.) After two unsuccessful attempts to 
establish the link, a MINOR alarm is raised for service attention. If the System 
Printer Link is torn down due to an error, System Printer Link Maintenance raises 
a MINOR alarm but does not attempt to bring up the System Printer Link.
In DEFINITY Generic 1, the following physical configurations are supported for 
the System Printer Link:
a. from the EIA port on the Processor circuit pack to a SYS-PRNT output 
device via the standard EIA 232C interface
b. from a data channel (DATA-CHL) on the Network Control circuit pack 
(DATA-BD) to a data extension where the SYS-PRNT output device 
connects via the standard EIA 232C interface
The data extension can be a(n) PDM, MPDM, DTDM, or ADU. The PDM, MPDM, 
or DTDM connects to a Digital Line (DIG-LINE) on the TN754 or TN754B Digital 
Line circuit pack (DIG-BD); the ADU connects to a Data Line (DAT-LINE) of the 
TN726 Data Line circuit pack (DT-LN-BD).
System Printer Link Maintenance does not cover the elements comprising the 
SYS-PRNT physical link; that is, the external SYS-PRNT output device, the EIA 
port on the Processor circuit pack, the Data Module (PDM/MPDM/DTDM) and the 
Digital Line of TN754 or TN754B Digital Line circuit pack, the ADU and the Data 
Line of TN726 Data Line circuit pack, and the data channels on the TN777 
MO Name (in 
Alarm Log)
Alarm Level
Initial Command 
to Run
Full Name of MO
SYS-PRNT
MINOR
test sp-link l
System Printer
SYS-PRNT
WARNING
release sp-link
System Printer