DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-10
busyout data-module 
8
Output
For the following output example, assume that the command that was entered is 
"busyout cdr-link primary."
Feature Interactions
None.
busyout data-module
This command will busyout a system technician specified data module or data 
channel.
Synopsis
busyout data-module extension
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being busied out. With this maintenance object a 
port address of 1 represents the primary link, while a 2 port 
address is associated with the secondary link.
Maintenance Name
The type of maintenance object that is being busied out.
Alt. Name
The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a station, and it 
contains xxx/yyy when the object is a trunk, where xxx is the trunk 
group number and yyy is the member number. It contains P/xxx 
when the object is a private CO line, where xxx is the private CO 
line group number.
Result
An indicator as to whether the object was successfully busied 
out.
Error Code
A numerical description of why the command failed.
 
 busyout cdr-link primary                           SPE A
                             COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   1        CDR-LNK                      PASS
 Command successfully completed