Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1362
TAPE (Tape Unit) [G3iV1.1-286] 
10
Tape Unit Aux Data/Error Codes Tables
100
FAIL
1. Do the steps below following the directions in the 
 
section.
2. Issue the
 test tape long 
command.
3. If the test fails, make sure tape is fully inserted.
4. If the test continues to fail, clean the tape head and 
retest.
5. If fail, swap tape and retest.
6. If the test still fails, swap tape unit, 
use original tape
 
and retest.
7. If the problem still exists, escalate the problem.
PASS
No block errors are detected.
Table 10-415.
Table A: Tape Unit Aux Data Table 
Aux Data/ 
Error Codes
Explanation
Strategy
9002
Internal system error.
Escalate the problem.
9003
Hardware not responding.
1. Follow the instructions provided in the 
 section.
2. If the problem still exists, escalate the 
problem.
9004 9005
Internal system error.
Escalate the problem.
Continued on next page
Table 10-414.
TEST #692 Tape Block Error Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page