Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1396
TDM-BUS (TDM Bus)
10
!
WARNING:
This command removes power and returns power to the designated
Medium cabinet port carrier. Thus, any other circuit packs on this carrier is
also temporarily taken out-of-service.
Medium cabinet port carrier. Thus, any other circuit packs on this carrier is
also temporarily taken out-of-service.
Error Log Entries and Test to Clear Values
NOTE:
For TDM-BUS, an ON-BOARD alarm refers to a problem with the TDM-BUS
itself.
For TDM-BUS, an ON-BOARD alarm refers to a problem with the TDM-BUS
itself.
Notes:
a. The TDM Bus has been busied out by the technician. The error retires
when the technician releases the TDM Bus.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
Table 10-420.
TDM Bus Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test tdm
1
0
Control Channel Test
(#296)
(#296)
MINOR
ON
test tdm P r 3
18 (a)
0
busyout tdm PC
WARNING
ON
release tdm PC
35 (b)
0-1
TDM Bus Corruption
MINOR
ON
set tdm PC
257 (c)
0
none
MAJOR
ON
513 (d)
Any
Idle Time Slot Test (#294)
MINOR
ON
test tdm P r 3
769 (e)
Any
Idle Time Slot Test (#294)
WARNING
ON
test tdm P r 3
769 (f)
Any
Idle Time Slot Test (#294)
(see Notes)
1025
Any
3872 (g)
Any
none
3873 (g)
Any
none
3874 (g)
Any
none
3877 (g)
Any
none