Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1410
TDM-CLK (TDM Bus Clock) 
10
TDM-CLK (TDM Bus Clock)
NOTE:
Replacing the tone/clock circuit pack requires a special procedure 
described in the documentation for TONE-BD. That section also describes 
the LED displays for this board.
The Time Division Multiplex (TDM) Bus Clock resides on the Tone-Clock circuit 
pack, providing clocking signals both for the TDM Bus and the LAN Bus. The 
Tone-Clock circuit pack is a critical component in the system and is necessary to 
ensure the operation of all port circuit packs in the system. The TDM buses of the 
PPN and any EPNs are synchronized together. The system timing reference can 
be derived internally from the Tone-Clock circuit pack in any PN, or from an 
external (off-board) timing reference. Currently, the TDM Bus Clock supports 
synchronizing the TDM Bus with interface rates from Digital Signal 1 (DS1) 
facilities as primary or primary and secondary references, and from Stratum 3 
Clock (STRAT-3) facilities. Only the TN780 tone-clock supports a Stratum 3 
clock.
Moreover, the Tone-Clock circuit pack aids in monitoring and selecting 
synchronization references. The Tone-Clock circuit pack, after detecting that the 
external source of timing is not valid, will automatically begin its escalation 
procedure, according to the facilities administered.
NOTE:
Switching back to a DS1 source is handled by synchronization 
maintenance, once any problems with it have been corrected and tested. 
However, once synchronization has been switched to the internal timing 
source of the master Tone-Clock circuit pack, 
switching back to a Stratum 3 
Clock must be initiated by a technician
 after the external reference has 
been repaired. 
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E).
MO Name (in 
Alarm Log)
Alarm Level
Initial Command To Run
1
Full Name of MO
TDM-CLK
MAJOR
test tone-clock UUC short
TDM Bus Clock
TDM-CLK
MINOR
test tone-clock UUC short
TDM Bus Clock
TDM-CLK
WARNING
release tone-clock UUC
TDM Bus Clock